• Georelief
  • Hillshade
  • Landsat

LEGEND


Transmission Lines

This dataset describes the information of transmission lines for each of Cambodia’s province from 2009 to 2015.

  • Total Transmission lines listed: 49
Map ID
Grid line size (KV)
Status
Date of EIA
Status of EIA
Description
Number of circuit
Cross section in mm2
Line lenght (Km)
Year of operation
Grant/Investor
Reference
1
230
Existing lines
Unknown
Unknown
Vietnam Border- Takeo Substation
2
400
50
2009
ADB-NDF
2
115
Existing lines
Unknown
Unknown
Kirirom I-KiriromIII
1
150
32
2012
BOT
3
230
Existing lines
Unknown
Unknown
Kampot Substation - TakeoSubstation
2
450
73
2011
KfW
4
230
Existing lines
Unknown
Unknown
Kampot Substation-Kamchay Hydropower Plant
2
400
11
2012
BOT
5
230
Existing lines
Jan-09
Feasibility study
Phnom Penh- Kampong Chhnang-Pursat- Battambong
2
630
297
2012
BOT
6
230
Existing lines
Unknown
Unknown
Pursat Substation- Osom Substation
2
630
132
2012
BOT
7
230
Existing lines
Unknown
Unknown
Kampot Substation -Stung Hav Substation
2
630
81.62
2013
ADB-JICA
8
230
Existing lines
Unknown
Unknown
GS6- Kampong Chhnang Substation
2
2x400
97.18
2013
BOT
9
230
Existing lines
Unknown
Unknown
Osom Substation-Lower Reussey Chrum Hydropower Plant
2
2x400
42
2013
BOT
10
230
Existing lines
Unknown
Unknown
Phnom Penh Loop line(WPP-SPP)
2
2x630
48
2014
China Exim Bank
11
230
Existing lines
Unknown
Unknown
Lower Upper Reussey Chrum Hydropower-Tatay Hydropower
2
2x400
38
2014
BOT
12
115
Existing lines
Unknown
Unknown
Banteay Meanchey Substation-Battambang Substation
1
400
53
2007
BOT
13
115
Existing lines
Unknown
Unknown
GS4-GS1
1
2x250
29.80
2009
WB
15
230
Existing lines
Unknown
Unknown
Atay Hydropower Plan- Osom Substation
2
630
17.80
2013
BOT
16
115
Existing lines
Unknown
Unknown
Stung Hav Substation- Shihanouk Ville Substation
2
400
11
2014
JICA
17
115
Existing lines
Unknown
Unknown
Chhuk Substation- Banteay Meas Substation
1
400
12
2014
EDC
18
115
Existing lines
Unknown
Unknown
GS3-GS2
1
2x250
11.85
1999
Unknown
19
115
Existing lines
Unknown
Unknown
Kampong Speu Substation-Kirirom I
1
150
65.04
2002
Unknown
20
115
Existing lines
Unknown
Unknown
GS1- Kampong Speu Substation
1
150
40.93
2002
Unknown
21
115
Existing lines
Unknown
Unknown
Thai Border-Substation IE
2
400
4
2007
Unknown
22
115
Existing lines
Unknown
Unknown
Substation IE-Substation Banteay Meanchey
2
400
43
2007
Unknown
23
115
Existing lines
Unknown
Unknown
Substation Banteay Meanchey-Substation Siemreap
1
400
85
2007
Unknown
24
230
Under construction
Unknown
Unknown
Kratie-Stung Treng
Unknown
Unknown
126
2012
INDIA
25
230
Under construction
Unknown
Unknown
Phnom Penh-Sihanoukville, along national road 4
Unknown
Unknown
220
2013
CHMC
26
230
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
27
115
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
28
230
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
51
115
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
29
230
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
31
115
Under construction
Unknown
Unknown
East Phnom Penh- Neakleung-Svay Rieng
Unknown
Unknown
120
2014
CHMC
32
115
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
33
230
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
34
115
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
35
230
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
36
230
Under construction
Unknown
Unknown
Kampong Cham-Kratie
Unknown
Unknown
110
2012
CUPL
37
230
Under study
Unknown
Unknown
Lao PDR (Ban Sok)-Stung Treng-Vietnam (Tay Ninh)
Unknown
Unknown
220
2019
ADB
38
115
Under construction
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
40
230
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
41
230
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
42
230
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
43
115
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
44
230
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
45
230
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
46
230
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
47
115
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
48
115
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
49
115
Under study
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
Unknown
50
230
Under study
Unknown
Unknown
Stung Treng-Lao PDR (construct substation in Stung Treng)
Unknown
Unknown
56
2012
WB
39
230
Existing lines
Unknown
Unknown
Takeo Substation-GS4
2
630
47
2009